TM
925 Freedom Blvd #444
Watsonville, CA 95076
Email: admin@pressurepak.com
Phone# (831) 786-9976













 


PRESSUREPAK™ Technical Data

Flow: Maximum 40 GPM (9 CMH)
Head: Maximum 300 feet/130 PSI (91 M)
Fluid Temperature: Maximum 95 degrees F (0 degrees C)
Ambient Temperature: Minimum 32 degrees F (0 degrees C)
Operating Pressure: Maximum 145 PSI
Inlet Pressure: Minimum flooded suction, Maximum limited by operating pressure
Operating Setpoint: 40 to 100 PSI (in 10 PSI increments)
Sound Pressure Level: External installation < 74 dB(A) at 3 feet from pump
With enclosure: various depending on enclosure type and insulation
Construction: Stainless steel pump casing and soldered copper plumbing
PRESSUREPAK™ Sizing Guide
  1. Determine approximately how much water pressure you have available at your water inlet.
  2. Determine how much water pressure you require at maximum flow.
  3. The pressure difference between you available pressure (1 above) and your required pressure (2 above) is the PSI Boost Needed for you.
  4. Select the model from the chart below that meets the PSI Boost Need for you.
PSI
Boost
Needed
Example: You currently have about 20 PSI at the water inlet and you want 60 PSI with a maximum flow of 15 GPM. Therefore the amount of boost needed is 40 PSI. In this case you need model number P15-05A-110.
Flow required in gallon per minute (GPM)
^ back to top
System Configurations


Base Setup includes a 15 GPM variable speed constant pressure pump capable of producing up to 70 PSI of addtional water pressure, a variable speed pump controller, a 2 gallon pressure tank and a power cut-off box, all in a galvanized steel box.

Upgrades are available including dual pump systems that meet flow standards for residential sprinkler system.

^ back to top